Review of Broseley eVolution 26 boiler stove

Smokes into the room when loading more logs

Chris Rudge 8 years ago

We installed an Evolution 26 a couple of years ago and the customer has had constant problems with smoke billowing into the room when the door is opened to load logs. I see from this review webpage that this is a constant problem with the Evo26 log boiler. In most other aspects it functions well.

To improve the flue draft, we re installed the flue last year, adding extra sections to exceed the Broseley requirements and now have a draft of 20 pascals. It still blows smoke!

It seems inside the boiler, there is probably too many baffles to allow the smoke to easily escape which cause the smoking problem.

Its a nice looking boiler, but if you value your decor, look for something else to buy.

Stove expert replied: Is there an air brick in the room to provide enough free air for combustion? It seems strange to have this problem when the flue draw appears to be adequate even greater than recommended for the product. Is there another chimney in the property that could have a better draw, (so when the balance is altered by opening the door, the flue does not have enough lift to take the smoke up the chimney)?

Overall rating:

2.5 flames

Build Quality 4 flames (avg 3.7)
Quality of finish 4 flames (avg 3.9)
Value for money 1 flames (avg 3)
Ease of use 1 flames (avg 2.9)
Ease of lighting 5 flames (avg 3.7)
Firebox size 5 flames (avg 4.4)
How well does the airwash work 1 flames (avg 2.9)
Controllability 2 flames (avg 2.9)
Handle operation 4 flames (avg 4.3)
How likely are you to buy it again? 1 flames (avg 3.1)
What is your overall satisfaction? 2 flames (avg 3.3)
  • Anthony Poole said 6 years ago:

    We have the same stove - we''ve had it for 7 years now and always had the same issue with smoke coming into the room. The issue with the stove is that the flue never gets really hot - which is what you need for a decent draw. The water cooled effect of the stove keeps the unit pretty cool during operation - unless of course you''re not passing water through it in which case you can ignore my comments. Cleaning is paramount. Our local chimney sweep gave up on us because of the difficulty of servicing the Broseley - taking the side panel off and getting access through the small side hatch is a time consuming process but one that should be done (we''ve found) twice a year to keep the flue clear. Debris falls down the flue straight onto the top baffle and the flue can become restricted very quickly. We resorted to buying our own chimney flue cleaning rods which attach to my cordless drill and I must say they do a better job than our local sweep ever did. So now I just clean the unit myself twice a year - takes me an hour or two but it''s well worth it. Your issue could be soot build up on the top baffle (pretty poor design from Broseley but it is what it is). When loading the unit do the following - open the door about a cm. You''ll notice the rush of air fans the embers and causes the fire to burn a little quicker. Let the fire stabilise - takes about 30 secs and then open the door really slowly. The smoke will go up the flue if you''re patient and don''t rush opening the door - it''s the vacuum effect when people open the door quickly that causes smoke to billow into the room - then people panic and shut the door - only to be back to square one. So my top tips are - make sure the unit is really clean in the area on top of the top baffle (directly under the flue) and practice opening the door slowly with that initial 30 second wait with the door open about a cm. Hope this helps - there''s nothing worse than a smoke filled room.