Review of Broseley eVolution 26 boiler stove
Broseley evolution
Had this stove fitted to a new bungalow chimney built to manufactures recommendation three years ago, this stove is the worst nightmare with smoke pouring into the room on reloading tried fitting rotating cowl without success, have now fitted eco boost flue fan at a cost of nearly a thousand pounds although a bit of improvement its far from ideal,t his stove I would not recommend.
Stove expert replied: I doubt it is the stove that is at fault but the installation that prevents the flue gases from lifting away from the firebox on opening of the door. Is there an air brick in the room? What height is the flue system and what is the construction.? Have you other flues in the property? Further investigation may improve this further as alternative remidies are normally possible once the cause if found.
- Respond
- 351 You and 490 others
- Show oldest comment first
- Show newest comment first
- Sort by most recommended
Anthony Poole said 6 years ago:
We have the same stove - we''ve had it for 7 years now and always had the same issue with smoke coming into the room. The issue with the stove is that the flue never gets really hot - which is what you need for a decent draw. The water cooled effect of the stove keeps the unit pretty cool during operation - unless of course you''re not passing water through it in which case you can ignore my comments. Cleaning is paramount. Our local chimney sweep gave up on us because of the difficulty of servicing the Broseley - taking the side panel off and getting access through the small side hatch is a time consuming process but one that should be done (we''ve found) twice a year to keep the flue clear. Debris falls down the flue straight onto the top baffle and the flue can become restricted very quickly. We resorted to buying our own chimney flue cleaning rods which attach to my cordless drill and I must say they do a better job than our local sweep ever did. So now I just clean the unit myself twice a year - takes me an hour or two but it''s well worth it. Your issue could be soot build up on the top baffle (pretty poor design from Broseley but it is what it is). When loading the unit do the following - open the door about a cm. You''ll notice the rush of air fans the embers and causes the fire to burn a little quicker. Let the fire stabilise - takes about 30 secs and then open the door really slowly. The smoke will go up the flue if you''re patient and don''t rush opening the door - it''s the vacuum effect when people open the door quickly that causes smoke to billow into the room - then people panic and shut the door - only to be back to square one. So my top tips are - make sure the unit is really clean in the area on top of the top baffle (directly under the flue) and practice opening the door slowly with that initial 30 second wait with the door open about a cm. Hope this helps - there''s nothing worse than a smoke filled room.